Adjustable Glass Stand-off Adapter
Adjustable Glass Stand-off Adapter
Adjustable Glass Stand-off Adapter

Adjustable Glass Stand-off Adapter

£34.21
(Exc. 20% VAT)
(£41.05 Inc. VAT)
+
Item Code
AD749S450
Material
Stainless Steel 304 or 316 Grade
Finish
Satin or Polished

CERTIFICATES: Quality & Safety Marks
      

Overview

Stainless Steel Glass Stand-off Fitting: 4D Adjustment, time saving, easy alignment: it lets you adjust and optimise glass alignment before and even during the installation.
Balustrade Infill: Glass; mounting type: fascia mount; application: balustrades, stairs; glass thickness: 8 - 25.52mm; location suitability: indoor, outdoor

Material: Stainless Steel 304 grade (for indoor) or 316 grade (for indoor & outdoor)*
Finish: Satin Brushed or Mirror Polished Finish 
Dimension: Ø50mm with 30mm, 40mm, 50mm and 100mm offset spacer
Glass Thickness: 8mm - 25.52mm
Hole Drilling in Glass:  Ø26mm

Interior use:

304 Grade (for Internal use)

Item Code Diameter H (mm) T (mm) Grade Finish
AD749S430 Ø50mm 30mm 12 - 25.52mm 304, Indoor Satin
AD749S440 Ø50mm 40mm 8 - 25.52mm 304, Indoor Satin
AD749S450 Ø50mm 50mm 8 - 25.52mm 304, Indoor Satin

Exterior use:

316 Grade (for Internal & External use)

Item Code Diameter H (mm) T (mm) Grade Finish
AD749S630 Ø50mm 30mm 12 - 25.52mm 316, Indoor & Outdoor Satin
AD749S640 Ø50mm 40mm 8 - 25.52mm 316, Indoor & Outdoor Satin
AD749S650 Ø50mm 50mm 8 - 25.52mm 316, Indoor & Outdoor Satin
AD749P650 Ø50mm 50mm 8 - 25.52mm 316, Indoor & Outdoor Mirror Polished
AD749S610 Ø50mm 100mm 8 - 25.52mm 316, Indoor & Outdoor Satin

*304 grade stainless steel suits interior use. With increased corrosion resistance, 316 grade stainless steel can be used for both interior and exterior and is better suited for coastal or more heavily polluted environments.

Technical Information

Adjustable Glass Stand-off Adapter - Line Load & Impact Test Report <Summary>

Introduction

This summary report describes tests conducted on Adjustable Glass Stand-off Adapters, assembled with various dimensions as shown in this report. The tests were done according to one or more of the following standards:  

Country Standards
United Kingdom BS-EN-1990, 1991, 1993, 1999, BSI 6180
Germany DIN- EN-1990, 1991, 1993, 1999, DIN 18008 Cat. A & B
France NF-EN-1990, 1991, 1993, 1999 EN-10204/ NF P 01-013

Test Arrangement

Various barrier specimens were mounted on to a rigid concrete structure with a test rig from steel with sufficient strength to withstand loads applied to it. 

For each test, load was applied to the glass in a hand railing height using a hydraulic ram. Load was measured with a load cell. A digital caliper was used to measure the deflection of the barrier from its neutral position. 


Test Materials

Adjustable Stainless Steel Glass Stand-off Adapter with Silicon Rubber Inlay;

Ø42.4mm Stainless Steel Slotted Handrail with Rubber Gasket for different glass thickness;

Glass Panels:

  • 15 mm monolithic with toughened 
  • 19 mm monolithic with toughened 
  • 12.76 (6mm-0,76-6mm) laminated with PVB film and toughened 
  • 16,76 (8mm-0,76-8mm) laminated with PVB film and toughened 
  • 17,52 (8mm-1,52-8mm) laminated with PVB film and toughened 
  • 20,76 (10mm-0,76-10mm) laminated with PVB film and toughened 
  • 21,52 (10mm-1,52-10mm) laminated with PVB film and toughened 
  • 25,52 (12mm-1,52-12mm) laminated with PVB film and toughened 

Max. Deflection Results Table

Glass Information (mm) Load Height Adapters  Information Line Load (kN/m)
Thickness (mm) QTY. Width x Height (MM) C.C (mm) QTY. h (mm) 0.36 0.50 0.74 0.80 1.00 1.50 2.00
15 1 1000 x 1350 1050 700 4 150 11.9 17.3 26.5 28.7 36.0 --   

15

1 1000 x 1350 1050 700 4 190 11.0 15.8 23.7 25.7 32.3 --  
15 1 1200 x 1350 1050 900 4 150 16.8 22.5 32.3 34.7 42.6 --  
15 1 1400 x 1350 1000 600+600 6 200 9.8 13.7 20.3 21.9 27.1 39.7  
19 1 1000 x 1350 1050 700 4 150 6.8 10.2 16.1 17.5 22.3 34.2  
19 1 1200 x 1350 1050 900 4 150 12.0 15.3 21.1 22.6 27.6 --  
19 1 1000 x 1350 1050 700 4 190 5.6 8.5 13.3 15.4 22.5 28.4  
19 1 1200 x 1350 1050 900 4 190 6.7 9.6 14.5 16.7 24.2 30.3  
(6-0,76-6) 1 1200 x 1400 1050 500+500 6 150 16.6 27.5 41.5 45.3 58.0    
(8-0,76-8) 2 900 x 1350 1060 600 4 190 14.7 21.8 34.0 37.3 48.2 75.5  
(8-0,76-8) 2 1100 x 1400 1100 800 4 150 27.4 31.4 50.9 51.8 66.5 --  
(8-0,76-8) 2 1300 x 1400 1100 1000 4 150 22.6 34.5 56.2 63.5 70.0 --  
(8-1.52-8) 1 1200 x 1400 1050 500+500 6 150 8.1 14.0 20.6 22.2 27.6 47.1  
(8-1.52-8) 2 1300 x 1350 1060 1000 4 190 19.3 27.7 42.3 45.9 58.2 --  
(8-1.52-8) 1 1400 x 1350 1000 600+600 6 200 14.2 17.4 31.2 34.1 44.0

68.0

 
(10-0.76-10) 2 1100 x 1350 1060 800 4 190 4.4 6.6 10.4 11.5 15.2 24.1 32.5
(10-0.76-10) 2 1300 x 1350 1060 1000 4 190 9.8 14.5 22.6 24.6 31.5 48.6  
(10-0.76-10) 2 1500 x 1350 1060 1200 4 190 10.0 14.7 22.8 25.3 33.5 53.1  
(10-1.52-10) 1 1100 x 1350 1000 800 4 190 7.3 11.0 17.2 18.7 23.8 36.5 48.5
(10-1.52-10) 2 1300 x 1400 1100 1000 4 150 14.4 23.2 35.8 41.5 48.0 68.4  
(10-1.52-10) 1 1500 x 13506 1000 1200 4 190 8.7 13.1 21.2 22.8 28.2 42.2  
(10-1.52-10) 2 1500 x 1400 1100 600+600 6 150 18.4 21.7 31.7 37.1 47.7 60.8  
(12-1.52-12) 1 2000 x 1400 1100 800+800 6 150 9.9 19.0 27.5 27.7 35.0 55.4 73.3

Introduction Impact Results Table

Glass Information (mm) Load Height Adapters  Information EN 12600 ISO-7892
Thickness (mm) QTY. Width x Height (MM) C.C (mm) QTY. h (mm) Fall Height (mm)
300 700 900

1000

1835
15 1 1000 x 1350 1050 700 4 150 N. t N. t N. t N. t N. t

15

1 1000 x 1350 1050 700 4 190 N. t N. t N. t N. t N. t
15 1 1200 x 1350 1050 900 4 150 N. t N. t N. t N. t N. t
15 1 1400 x 1350 1000 600+600 6 200 N. t N. t N. t N. t N. t
19 1 1000 x 1350 1050 700 4 150 N. t N. t N. t N. t N. t
19 1 1200 x 1350 1050 900 4 150 N. t N. t N. t N. t N. t
19 1 1000 x 1350 1050 700 4 190 N. t N. t N. t N. t N. t
19 1 1200 x 1350 1050 900 4 190 N. t N. t N. t N. t N. t
(6-0,76-6) 1 1200 x 1400 1050 500+500 6 150 -- -- -- --  
(8-0,76-8) 2 900 x 1350 1060 600 4 190 -- -- -- -- --
(8-0,76-8) 2 1100 x 1400 1100 800 4 150 -- -- -- -- --
(8-0,76-8) 2 1300 x 1400 1100 1000 4 150 passed -- -- -- --
(8-1.52-8) 1 1200 x 1400 1050 500+500 6 150 -- -- -- -- --
(8-1.52-8) 2 1300 x 1350 1060 1000 4 190 -- -- -- -- --
(8-1.52-8) 1 1400 x 1350 1000 600+600 6 200 passed -- -- --

--

(10-0.76-10) 2 1100 x 1350 1060 800 4 190 passed passed -- passed passed
(10-0.76-10) 2 1300 x 1350 1060 1000 4 190 passed passed -- passed passed
(10-0.76-10) 2 1500 x 1350 1060 1200 4 190 passed passed -- passed passed
(10-1.52-10) 1 1100 x 1350 1000 800 4 190 passed passed -- passed passed
(10-1.52-10) 2 1300 x 1400 1100 1000 4 150 passed   -- passed passed
(10-1.52-10) 1 1500 x 13506 1000 1200 4 190 passed passed -- passed passed
(10-1.52-10) 2 1500 x 1400 1100 600+600 6 150 passed -- -- passed passed
(12-1.52-12) 1 2000 x 1400 1100 800+800 6 150 passed -- -- passed passed
 

Comments:

Line Load test: The loading was applied to the top of glass and the deflection was measured at the same height. 

Impact test: The impact test was done with two different impactors having the mass of 50 kg as follows: 
  • with the EN-12600 impactor at fall heights of 450, 700 and 900 mm 
  • with the ISO-7892 impactor at fall heights of 1000 and 1835 mm 

Please Note: this is an abstract of the test report. Full test report available upon request.